The criteria used were based on the local accessible design standard adopted with reference to the “Design Manual Barrier Free Access 2008” published by the Buildings Department of Hong Kong.
|
| RAMP: |
Maximum gradient 1 in 12
|
| CORRIDOR / PASSAGE: |
Minimum clear width of 1050 mm
|
| COUNTER: |
Maximum height of 750 mm
|
| DOOR: |
Minimum clear width of 800 mm
|
| LIFT: |
Minimum door width of 850mm
Minimum internal space of 1200x1100mm
Maximum height of control panel 1200mm
|
| TURNING SPACE FOR WHEELCHAIR: |
minimum area of 1500 x 1500mm
|
| TOILET CUBICLE: |
Minimum door width of 800 mm
Minimum internal area of 1500mm x 1750mm
With grab bar, wash basin accessible to wheelchair
|
| CHANGE IN LEVELS: |
Passageway should be ramped in passageway
|
| CAR PARK: |
Specific parking space reserved which is accessible to a lift
|
| DIAL AND HANDSET OF PUBLIC TELEPHONE: |
Maximum height of 1200 mm
|
| SEATING SPACE FOR WHEELCHAIR USER: |
no less than 800 mm x 1300 mm
|